Click to skip the navigation bar

Table of Contents

ES210X-M2(UN)_Multi-model_Installation Guide

For simplicity, we will take ES210X-M2 for example throughout the Guide. The images in this guide are for demonstration only and may differ from your actual product.

1 Installation

Desktop Installation

Attach the supplied rubber feet to the bottom of the switch to prevent it from slipping when placed on a desktop.

Desktop Installation

Wall-Mounting Installation

Drill two holes on the wall according to the mounting holes on the bottom of the switch, then secure the switch to the wall with two suitable screws (not provided).

Note:

For detailed information, please refer to the Wall Mounting Guide.

Wall-mounting installation

2 Connection

connection

3 Configuration

The switch supports two configuration methods: 

· Standalone Mode: Configure and manage the switch individually. To set up a standalone Omada switch, refer to https://www.omadanetworks.com/support/faq/4097/.

· Controller Mode: Configure and manage the network devices centrally. This mode is recommended for large-scale networks with numerous devices, including access points, switches, and gateways. To set up an Omada switch with an Omada Controller, refer to the Omada Controller configuration guide at https://www.omadanetworks.com/support/faq/4096/.

Omada App

With the TP-Link Omada app, you can access and manage your Omada devices at a local site or remotely with a tap of your phone. You can download and install the TP-Link Omada app from the App Store or Google Play.

apple storegoogle storeomada app

For detailed instructions on device configuration, refer to the user guides of the Controller and switches. The guides can be found in the support center of our official website: https://support.omadanetworks.com/document/.

4 LED Explanation

Power On/Off: Power on/off

Link/Act (2.5G)

(For ports 1-5 of ES206X-M2
/ports 1-8 of ES210X-M2)

On (Green): Running at 2.5 Gbps
Blinking: Transmitting/receiving data
Off: No connected device
Link/Act (1G/100M)
(For ports 1-5 of ES206X-M2
/ports 1-8 of ES210X-M2)
On (Green): Running at 1000 Mbps
On (Yellow): Running at 100 Mbps
Blinking: Transmitting/receiving data
Off: No connected device
SFP+
(For port 6 of ES206X-M2
/ports 9-10 of ES210X-M2)
On (Green): Running at 10 Gbps
On (Yellow): Running at 1000 Mbps
Blinking: Transmitting/receiving data
Off: No connected device

 

5 Specifications

General Specifications
Standard IEEE 802.3, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3z, IEEE 802.3bz, IEEE 802.3ae, IEEE 802.3az, IEEE 802.3x, IEEE 802.1p, IEEE 802.1q
Interface For ES206X-M2: 
5 100M/1G/2.5Gbps RJ45 Ports
1 10G SFP+ Port 
For ES210X-M2: 
8 100M/1G/2.5Gbps RJ45 Ports
2 10G SFP+ Ports 
Transmission Media 100BASE-TX: UTP category 5, 5e cable (maximum 100 m)
1000BASE-T: UTP category 5e cable or above (maximum 100 m)
1000BASE-SX: 62.5 μm MMF (2 m ~ 275 m) or 50 μm MMF (2 m ~ 550 m) 
1000BASE-LX: 62.5/50 μm MMF (2 m ~ 550 m) or 9 μm SMF (2 m ~ 5000 m) 
1000BASE-LX10: B1.1, B1.3 SMF (2 fiber) (0.5 m ~ 10000 m)
1000BASE-BX10: B1.1, B1.3 SMF (1 fiber) (0.5 m ~ 10000 m)
2.5GBASE-T: UTP category 5e cable or above (maximum 100 m)
10GBASE-SR: OM1/OM2/OM3 or above MMF (2 m ~ 300 m)
10GBASE-LR: IEC B1.1 and B1.3 SMF (2 m ~ 10 km)
Switching Capacity ES206X-M2: 45 Gbps
ES210X-M2: 80 Gbps
Transfer Method Store-and-Forward
MAC Address Learning Automatically learning, automatically aging
Power Supply Input: 100-240 VAC, 50/60 Hz
Output: 
ES206X-M2: 12 V DC/1 A
ES210X-M2: 12 V DC/1.5 A
Wall Mountable Yes
Distance Between Mounting Holes ES206X-M2: 94 mm
ES210X-M2: 150 mm
Environmental and Physical Specifications 
Operating Temperature -5 ˚C to 40 ˚C (32 ˚F to 104 ˚F) 
Storage Temperature -40 ˚C to 70 ˚C (-40 ˚F to 158 ˚F)
Operating Humidity 10% RH to 90% RH non-condensing
Storage Humidity 5% RH to 90% RH non-condensing

 

6 Frequently Asked Questions (FAQ)

Q1. The Power LED is not lit.
The Power LED should be lit when the power system is working normally. If the Power LED is not lit, please check as follows:
A1: Make sure the switch and power source are properly connected through the power adapter.
A2: Make sure the power source voltage meets the input voltage requirements of both the power adapter and the switch. 
A3: Make sure the power source is on. 

Q2. Why is the Link/Act LED not lit while a device is connected to the corresponding port?
It is recommended that you check the following items:
A1: Make sure that the cable connectors are firmly plugged into the switch and the device.
A2: Make sure the connected device is turned on and working well. 
A3: The cable must be less than 100 meters (328 feet) long. If Extend Mode is enabled, it should be less than 250 meters (820 feet).