Letöltés - EAP225
>Hol található a TP-Link termékeken a hardver verzió?
- Termék áttekintése
- Használati útmutató
-
- Omada Controller Software 3.0.5_Windows/Linux_User Guide
- Omada Controller Software 3.1.4_User Guide
- Omada Controller Software 3.2.1_User Guide
- Omada Controller Software 3.1.13_User Guide
- Indoor APs(EU2-12Languages)_ Installation Guide
- Omada Controller Software 3.0.2_User Guide
- Omada Controller Software 2.7.0_User Guide
- Omada Controller Software 2.6.0_User Guide
- EAP Controller_V2.4.8_User Guide
- EAP225(UN)_V2_User Guide
- EAP225(UN)_V2_Installlation Guide
Beállítási videó
-
How to Set up a TP-Link EAP via Web browser
This video will demonstrate how to set up a TP-Link EAP via a web browser. The setup consists of three steps:
1. Connect the EAP to the network
2. Log into the EAP (via a wired/wireless connection)
3. Change the default SSID
This video is suitable for users with a small number (1-3) of EAPs .
Learn More
GYIK
- How to Build a Mesh Network via Omada EAP in Your Home
- What should I do when the Omada Software Controller (V3 or below) fails to discover the EAP?
- How to choose EAP products
- How to manage EAPs at different sites across Internet using Omada Controller (via NAT Port Forwarding for Controller Host with DHCP Option138)? (Old UI)
- How to manage EAPs at different sites across Internet using Omada Controller (via NAT Port Forwarding for Controller Host with EAP Discover Utility)? (Old UI)
- How to configure basic wireless settings of my TP-Link EAP in Standalone mode?
- What is TP-Link EAP Beamforming?
- How to configure basic wireless settings of my TP-Link EAP via Omada Controller?
- Common questions about TP-Link EAP device when it’s used in home network
- How to set Access Control to create guest SSID on Omada Controller/EAP
- What if I forget the password of EAP Controller?
- What is TP-Link EAP/CAP MU-MIMO?
- How to Configure Omada Controller as a Windows Service(above Controller 2.5.4)
- The Requirements of Establishing an External Portal Server (above Omada Controller 2.6.0)
- What is Fast Roaming of TP-Link Business Wi-Fi Products?
- How to adopt EAP in Controller Mode?
- Q&A for TP-Link Omada App
- How to manage EAPs at different places across internet using Omada Controller (via NAT Port Forwarding and EAP Discovery Utility)? (New UI)
- How to manage EAPs at different places across Internet using Omada Controller (via NAT Port Forwarding and DHCP Option 138)? (New UI)
- Do I need to keep controller running when using portal authentication?
- How to Install TP-Link Omada Discovery Utility on Windows and macOS PCs?
- How to manage EAPs in different VLANs using Omada Controller? (Old UI)
- How to manage EAPs at different sites across Internet using Omada Controller (via VPN Tunnel with DHCP Option138)? (Old UI)
- How to manage EAPs at different sites across Internet using Omada Controller (via VPN Tunnel with EAP Discover Utility)? (Old UI)
- How to manage EAPs in different subnets using Omada Controller (via DHCP option 138)? (Old UI)
- How to manage EAPs in different subnets using Omada controller (via EAP Discover Utility)? (Old UI)
- How to manage EAPs in different subnets using Omada controller (via EAP Discovery Utility)? (New UI)
- Frequently asked questions of EAP Series Access Points
- How to view detailed client information of an EAP?
- How to set up rate limit through EAP controller
- What Is the Difference Between Login Account, Cloud Account, Device Account and User Account in Omada Controller?
- How do I login to the web management page of the EAP Series products (Standalone mode)?
- How to configure the WLAN Group function on the Software Controller (or OC200)
- Troubleshooting of Wireless Issues for Omada EAP Products
- How to back up and restore the configuration and data of your Software Controller (or OC200)
- How to configure the portal function on Omada Controller?
- How to optimize wireless performance of EAP products
- Will the Configuration Still Work with EAPs When the Omada Controller Goes Offline?
- How to Configure Voucher Authentication on Omada Controller?
- How to set up different SSIDs and Passwords for each EAP through EAP Controller?
- Source code template for External Web Portal (Controller 3.0.5 or below)
- The Requirements of Establishing an External Portal Server (below Omada Controller 2.5.4)
- What Can I Do If I Fail to Log In to the EAP via the Domain Name?
- Source code template for External Web Portal (Standalone Mode)
- What should I do if I got a certificate error?
- Configure rogue AP detection on EAP/Omada Controller
- How to Change the Language of the Printed Voucher Code?
- How to Configure Load Balance Omada Controller?
- How to Configure Reboot schedule and Wi-Fi Scheduler function of Omada Controller?
- How do I upgrade the firmware of my EAP device via web browser?
- How do I find the firmware version of my EAP device?
- How to configure free authentication policy on EAP Controller
- What is TP-Link EAP/CAP Airtime Fairness?
- How to Configure Band Steering on TP-Link Omada Controller?
- What should be noticed when running the EAP Controller for the first time?
- How to configure Multiple SSIDs with Multiple Subnets on EAP products
- How to deploy EAP controller on a private cloud (AWS EC2)?
- How to build a Wireless Network for School Canteen using tp-link products?
- How to build a Wireless Network for Chain Store using tp-link products?
- How to build a Factory Network using TP-Link products?
- How to build a Wireless Network for Shopping Mall using tp-link products?
- How to build a Wireless Network for Dormitory using tp-link products?
- How to build a Network for Restaurant & Cafe using tp-link products?
- How to build a Campus Network using TP-LINK products?
- How to Manage EAPs at Different Locations
- How to Change the Default Ports for EAP Controller?
- Hotspot authentication for multiple subnet with different VLANs
Firmware
A firmware frissítés megoldást kínál olyan problémákra, amikkel az előző verzió esetleg rendelkezett, ill. egyes funkciók hozzáadását és fejlesztését teszi lehetővé.
Frissítés
FONTOS: A frissítéskor legyen körül tekintő, hogy elkerülje a készülék használhatatlanná válását, és kövesse az alábbi útmutatót a helyes frissítési folyamathoz:
- Kérjük, ellenőrizze a készülék hardver verzióját a megfelelő firmware verzió eléréséhez. A helytelen firmware frissítés károsíthatja a készüléket, és érvényteleníti a garanciát. (Általában v1.x = V1);
Nem ajánlatos ezzel a firmware-rel frissíteni olyan készülékez, aminek régió megjelölése eltérő. Kérjük, keresse ki itt az ön régióját a legmegfelelőbb firmware kiválasztásához. (Pl.: az EU és a US megjelölésű firmware-ek eltérnek egymástól) - NE kapcsolja ki a készüléket a frissítés ideje alatt, mert ezzel visszafordíthatatlan károsodást okoz.
- NE frissítse a firmware-t vezeték nélküli (Wi-Fi) kapcsolattal, kivéve ha TP-LINK készülék csak a vezeték nélküli kapcsolattal rendelkezik.
- Javasolt, hogy a frissítés megkezdése előtt közvetlenül a felhasználó minden, az internet kapcsolatot használó alkalmazást leállítson a számítógépen, vagy egyszerűen húzza ki az internetet szolgáltató kábelt a TP-LINK készülékből.
- Használjon a frissítéshez letöltött tömörített fájlok kicsomagolásához például WinZip vagy WinRAR szoftvert.
- A letölthető frissítést tartalmazó tömörített fájlt (jellemzően .zip), valamint kicsomagoláskor a frissítést tartalmazó fájlt (jellemzően .bin) olyan helyre mentse a PC/Laptopon, ahol könnyen megtalálja (javasolt az Asztal/Desktop megadása mint mentési hely, ha lehetséges).
EAP225(EU)_V2_1.4.0 Build 180323 | |||
---|---|---|---|
Kiadás dátuma: 2018-04-13 | Nyelv: Angol | Fájlméret: 8.12MB | |
|
EAP225(EU)_V2_180208 | |||
---|---|---|---|
Kiadás dátuma: 2018-02-24 | Nyelv: Angol | Fájlméret: 7.96 MB | |
|
EAP225(EU)_V2_170828 | |||
---|---|---|---|
Kiadás dátuma: 2017-08-28 | Nyelv: Angol | Fájlméret: 7.90 MB | |
|
Harmadik fél által fejlesztett firmware használata TP-Link termékkel
Néhány hivatalos TP-Link termék firmware-e helyettesíthető harmadik fél által fejlesztett firmware verzióval, mint pl.: DD-WRT. Ilyen esetekben a TP-Link nem nyújt támogatást a készülékhez, és annak használata nem garantálja a teljesítményt és a stabil működést. A harmadik fél által készített firmware okozta készülékkárosodásért a TP-Link nem vállal felelősséget, és a készülékre vonatkozó garancia teljes elvesztésével jár. Kérjük, ezeket a firmware verziókat a fentiek figyelembe vételével, és csak is saját felelősségre használja!
Nyílt forráskód programozóknal (GPL)
Az alábbi információk a programozóknak szól, a legtöbb otthoni felhasználót nem érinti.
A TP-LINK termékek részben tartalmaznak harmadik fél által fejlesztett szoftverkódot, beleértve a GNU General Public License ("GPL"), 1-es verzió/2-es verzió/3-as verzió vagy GNU General Public License ("LGPL") alátartozó szoftvert kódokat.
A megfelelő GPL licenc feltételeket megnézheti, kinyomtathatja és letöltheti innen.Ezzel a TP-LINK egy ingyenesen letölthető példányt biztosít a megfelelő szoftver forráskóddal az adott a TP-LINK termékhez, valamint információt, hogy mely termékek rendelkeznek GPL szoftverkóddal, amit a GPL Code Center alatt is megtekinthet.
A vonatkozó programok GARANCIA NÉLKÜL kerülnek terjesztésre; a felhasználó saját felelősségre használhatja azokat, a ROSSZ FELHASZNÁLÁSBÓL eredő károkért a TP-LINK nem vállal felelősséget. Tekintse meg a vonatkozó GNU General Public License további részleteit.
Vezérlőprogram
The EAP Controller is used to manage multiple EAPs intensively.
Kiadás dátuma: 2020-12-25 | Nyelv: Angol | Fájlméret: 125.65MB |
Operációs rendszer: Ubuntu 14.04/16.04/17.04/18.04, CentOS 6.x/7.x and Fedora 20 or above |
||
Bundled Firmware: Bug Fixed: Notes: |
Kiadás dátuma: 2020-12-25 | Nyelv: Angol | Fájlméret: 99.43MB |
Operációs rendszer: Ubuntu 14.04/16.04/17.04/18.04, CentOS 6.x/7.x and Fedora 20 or above |
||
Bundled Firmware: Bug Fixed: Notes: |
Kiadás dátuma: 2020-12-25 | Nyelv: Angol | Fájlméret: 120.55MB |
Operációs rendszer: Windows 7/8/10/Server |
||
Bundled Firmware: Bug Fixed: Notes: |
Kiadás dátuma: 2020-12-25 | Nyelv: Angol | Fájlméret: 124.47MB |
Operációs rendszer: Windows 7/8/10/Server |
||
Bundled Firmware: Bug Fixed: Notes: |
Kiadás dátuma: 2020-04-20 | Nyelv: Angol | Fájlméret: 120.54MB |
Operációs rendszer: Windows 7/8/10/Server |
||
New Feature/Enhancement: 1. Added the feature that the system logs can be exported. 2. Changed the priority that non-administrator role cannot change the history data retention settings. 3. Optimized the UI of Statistics in Omada Controller.
Bug Fixed: 1. Fixed the bug that the External Web Portal cannot authenticate successfully if the SSID of this portal has special characters. 2. Fixed the bug that the Cloud Access cannot be displayed normally in the low version of Firefox. 3. Fixed the bug that Omada Controller allow any user to read the files of controller. 4. Fixed the bug that controller will report an error when Top Usage data is empty.
Notes: 1. To use Omada Controller 3.2.X new features, you need to upgrade your EAP's firmware to the corresponding version. 2. Once upgraded to this version of Omada Controller, you will NOT able to downgrade to an earlier version. 3. Portal configuration will be lost after upgraded to Omada Controller 3.2.X from 2.4.X or earlier version. |
Kiadás dátuma: 2020-04-20 | Nyelv: Angol | Fájlméret: 124.46MB |
Operációs rendszer: Windows 7/8/10/Server |
||
New Feature/Enhancement: 1. Added the feature that the system logs can be exported. 2. Changed the priority that non-administrator role cannot change the history data retention settings. 3. Optimized the UI of Statistics in Omada Controller.
Bug Fixed: 1. Fixed the bug that the External Web Portal cannot authenticate successfully if the SSID of this portal has special characters. 2. Fixed the bug that the Cloud Access cannot be displayed normally in the low version of Firefox. 3. Fixed the bug that Omada Controller allow any user to read the files of controller. 4. Fixed the bug that controller will report an error when Top Usage data is empty.
Notes: 1. To use Omada Controller 3.2.X new features, you need to upgrade your EAP's firmware to the corresponding version. 2. Once upgraded to this version of Omada Controller, you will NOT able to downgrade to an earlier version. 3. Portal configuration will be lost after upgraded to Omada Controller 3.2.X from 2.4.X or earlier version. |
Kiadás dátuma: 2020-04-20 | Nyelv: Angol | Fájlméret: 99.4MB |
Operációs rendszer: Ubuntu 14.04/16.04/17.04/18.04/Debian 9.8 |
||
Bug Fixed: 1. Fixed the bug that Omada Controller allow any user to read the files of controller. 2. Fixed the bug that controller will report an error when Top Usage data is empty.
Notes: 1. To use new features on Omada Controller 3.2.X, you need to upgrade your EAP's firmware to the corresponding version. 2. The Omada Controller program needs to use the system's netstat command. If the Linux system does not have net-tools installed (which contain the netstat command), the program may not be able to run normally. 3. Support 64-bit Linux operating system including Ubuntu 14.04/16.04/17.04/18.04/Debian 9.8 4. Built-in JRE 1.8 Java environment. 5. Once upgraded to this version of Omada Controller, you will NOT able to downgrade to an earlier version. 6. Portal configuration will be lost after upgraded to Omada Controller 3.2.X from 2.4.8. |
Kiadás dátuma: 2020-04-20 | Nyelv: Angol | Fájlméret: 125.64MB |
Operációs rendszer: Ubuntu 14.04/16.04/17.04/18.04, CentOS 6.x/7.x and Fedora 20 or above, Debian 9.8. |
||
Bug Fixed: 1. Fixed the bug that Omada Controller allow any user to read the files of controller. 2. Fixed the bug that controller will report an error when Top Usage data is empty.
Notes: 1. To use new features on Omada Controller 3.2.x, you need to upgrade your EAP's firmware to the corresponding version. 2. The Omada Controller program needs to use the system's netstat command. If the Linux system does not have net-tools installed (which contain the netstat command), the program may not be able to run normally. 3. Support 64-bit Linux operating system including Ubuntu 14.04/16.04/17.04/18.04, CentOS 6.x/7.x and Fedora 20 or above, Debian 9.8. 4. Built-in JRE 1.8 Java environment. 5. Once upgraded to this version of Omada Controller, you will NOT able to downgrade to an earlier version. 6. Portal configuration will be lost after upgraded to Omada Controller 3.2.X from 2.4.8. 7. When upgrading from Controller 2.5.3 Linux to this version via install.sh, you need to uninstall old version of Controller first. |
Kiadás dátuma: 2020-04-09 | Nyelv: Angol | Fájlméret: 99.39MB |
Operációs rendszer: Ubuntu 14.04/16.04/17.04/18.04/Debian 9.8 |
||
New Feature/Enhancement: 1. Add the feature that the system logs can be exported. 2. Change the priority that non-administrator role cannot change the history data retention settings. 3. Optimize the UI of Statistics in Omada Controller.
Bug Fixed: 1. Fix the bug that the External Web Portal cannot authenticate successfully if the SSID of this portal has special characters. 2. Fix the bug that the Cloud Access cannot be displayed normally in the low version of Firefox.
Notes: 1. To use new features on Omada Controller 3.2.X, you need to upgrade your EAP's firmware to the corresponding version. 2. The Omada Controller program needs to use the system's netstat command. If the Linux system does not have net-tools installed (which contain the netstat command), the program may not be able to run normally. 3. Support 64-bit Linux operating system including Ubuntu 14.04/16.04/17.04/18.04/Debian 9.8 4. Built-in JRE 1.8 Java environment. 5. Once upgraded to this version of Omada Controller, you will NOT able to downgrade to an earlier version. 6. Portal configuration will be lost after upgraded to Omada Controller 3.2.X from 2.4.8. |
Kiadás dátuma: 2020-04-09 | Nyelv: Angol | Fájlméret: 123.36MB |
Operációs rendszer: Ubuntu 14.04/16.04/17.04/18.04, CentOS 6.x/7.x and Fedora 20 or above, Debian 9.8. |
||
New Feature/Enhancement: 1. Add the feature that the system logs can be exported. 2. Change the priority that non-administrator role cannot change the history data retention settings. 3. Optimize the UI of Statistics in Omada Controller.
Bug Fixed: 1. Fix the bug that the External Web Portal cannot authenticate successfully if the SSID of this portal has special characters. 2. Fix the bug that the Cloud Access cannot be displayed normally in the low version of Firefox.
Notes: 1. To use new features on Omada Controller 3.2.x, you need to upgrade your EAP's firmware to the corresponding version. 2. The Omada Controller program needs to use the system's netstat command. If the Linux system does not have net-tools installed (which contain the netstat command), the program may not be able to run normally. 3. Support 64-bit Linux operating system including Ubuntu 14.04/16.04/17.04/18.04, CentOS 6.x/7.x and Fedora 20 or above, Debian 9.8. 4. Built-in JRE 1.8 Java environment. 5. Once upgraded to this version of Omada Controller, you will NOT able to downgrade to an earlier version. 6. Portal configuration will be lost after upgraded to Omada Controller 3.2.X from 2.4.8. 7. When upgrading from Controller 2.5.3 Linux to this version via install.sh, you need to uninstall old version of Controller first. |
Kiadás dátuma: 2019-11-08 | Nyelv: Angol | Fájlméret: 99.4MB |
Operációs rendszer: Ubuntu 14.04/16.04/17.04/18.04/Debian 9.8 |
||
New Feature/Enhancement: 1. Add “Select Page” feature on voucher management page. 2. Change default status of “Terms of Service” on default portal page to uncheck. 3. Optimize the “Free Authentication Policy” to support URL with suffixes. 4. Change the default status of new added “Free Authentication Policy” to enable.
Bug Fixed: 1. Fixed the bug that when clients disconnect from the Facebook portal, the connection time and traffic usage of these clients may be zero in the log. 2. Fixed the bug that AP may disconnect from Omada Controller when it is upgrading the firmware. 3. Fixed the bug that in some cases, the channel configuration of 2.4G frequency may show up in 5G by mistake. 4. Fixed the bug that the configuration of SSID will not be issued correctly when changing the WLAN Group on the provisioning status.
Notes: 1. To use new features on Omada Controller 3.2.X, you need to upgrade your EAP's firmware to the corresponding version. 2. The Omada Controller program needs to use the system's netstat command. If the Linux system does not have net-tools installed (which contain the netstat command), the program may not be able to run normally. 3. Support 64-bit Linux operating system including Ubuntu 14.04/16.04/17.04/18.04/Debian 9.8 4. Built-in JRE 1.8 Java environment. 5. Once upgraded to this version of Omada Controller, you will NOT able to downgrade to an earlier version. 6. Portal configuration will be lost after upgraded to Omada Controller 3.2.X from 2.4.8. |
Kiadás dátuma: 2019-11-08 | Nyelv: Angol | Fájlméret: 123.35MB |
Operációs rendszer: Ubuntu 14.04/16.04/17.04/18.04, CentOS 6.x/7.x and Fedora 20 or above, Debian 9.8. |
||
New Feature/Enhancement: 1. Add “Select Page” feature on the management page of vouchers. 2. Change the default status of “Terms of Service” to uncheck. 3. Optimize the “Free Authentication Policy” to support URL with suffixes. 4. Change the default status of new added “Free Authentication Policy” to enable.
Bug Fixed: 1. Fixed the bug that when clients disconnect from the Facebook portal, the connection time and traffic usage of these clients may be zero in the log. 2. Fixed the bug that AP may disconnect from Omada Controller when it is upgrading the firmware. 3. Fixed the bug that in some cases, the channel configuration of 2.4G frequency may show up in 5G by mistake. 4. Fixed the bug that the configuration of SSID will not be issued correctly when changing the WLAN Group on the provisioning status.
Notes: 1. To use new features on Omada Controller 3.2.x, you need to upgrade your EAP's firmware to the corresponding version. 2. The Omada Controller program needs to use the system's netstat command. If the Linux system does not have net-tools installed (which contain the netstat command), the program may not be able to run normally. 3. Support 64-bit Linux operating system including Ubuntu 14.04/16.04/17.04/18.04, CentOS 6.x/7.x and Fedora 20 or above, Debian 9.8. 4. Built-in JRE 1.8 Java environment. 5. Once upgraded to this version of Omada Controller, you will NOT able to downgrade to an earlier version. 6. Portal configuration will be lost after upgraded to Omada Controller 3.2.X from 2.4.8. 7. When upgrading from Controller 2.5.3 Linux to this version via install.sh, you need to uninstall old version of Controller first. |
Kiadás dátuma: 2019-11-08 | Nyelv: Angol | Fájlméret: 120.52MB |
Operációs rendszer: Windows 7/8/10/Server |
||
New Feature/Enhancement: 1. Add “Select Page” feature on the voucher management page. 2. Change the default status of “Terms of Service” on default portal page to uncheck. 3. Optimize the “Free Authentication Policy” to support URL with suffixes. 4. Change the default status of new added “Free Authentication Policy” to enable.
Bug Fixed: 1. Fixed the bug that when clients disconnect from the Facebook portal, the connection time and traffic usage of these clients may be zero in the log. 2. Fixed the bug that AP may disconnect from Omada Controller when it is upgrading the firmware. 3. Fixed the bug that in some cases, the channel configuration of 2.4G frequency may show up in 5G by mistake. 4. Fixed the bug that the configuration of SSID will not be issued correctly when changing the WLAN Group on the provisioning status.
Notes: 1. To use Omada Controller 3.2.x new features, you need to upgrade your EAP's firmware to the corresponding version. 2. Once upgraded to this version of Omada Controller, you will NOT be able to downgrade to an earlier version. 3. Portal configuration will be lost after upgrading to Omada Controller 3.2.X from 2.4.X or earlier version. 4. You are recommended to create a backup before upgrading, or you will not be permitted to install this version of Omada Controller. |
Kiadás dátuma: 2019-11-08 | Nyelv: Angol | Fájlméret: 124.43MB |
Operációs rendszer: Windows 7/8/10/Server |
||
New Feature/Enhancement: 1. Add “Select Page” feature on the voucher management page. 2. Change the default status of “Terms of Service” on default portal page to uncheck. 3. Optimize the “Free Authentication Policy” to support URL with suffixes. 4. Change the default status of new added “Free Authentication Policy” to enable.
Bug Fixed: 1. Fixed the bug that when clients disconnect from the Facebook portal, the connection time and traffic usage of these clients may be zero in the log. 2. Fixed the bug that AP may disconnect from Omada Controller when it is upgrading the firmware. 3. Fixed the bug that in some cases, the channel configuration of 2.4G frequency may show up in 5G by mistake. 4. Fixed the bug that the configuration of SSID will not be issued correctly when changing the WLAN Group on the provisioning status.
Notes: 1. To use Omada Controller 3.2.x new features, you need to upgrade your EAP's firmware to the corresponding version. 2. Once upgraded to this version of Omada Controller, you will NOT be able to downgrade to an earlier version. 3. Portal configuration will be lost after upgrading to Omada Controller 3.2.X from 2.4.X or earlier version. 4. You are recommended to create a backup before upgrading, or you will not be permitted to install this version of Omada Controller. |
Kiadás dátuma: 2019-07-04 | Nyelv: Angol | Fájlméret: 120.29MB |
Operációs rendszer: Windows 7/8/10/Server |
||
New Feature/Enhancement: 1. Optimize the performance of Controller to manage up to 1500 EAPs. 2. Optimize the interactive process between EAP and Controller to decrease the process time. 3. Limit the entry number of client/client history/guest to 1.2 million/1.2 million /6 million. 4. Optimize display page of map and log when there are a lot of entries.
Bug Fixed: 1. Fixed the bug that CPU and memory may be highly used when Fast Roaming is enabled. 2. Fixed the bug that Omada Controller reports timeout error when adopting multiple EAPs simultaneously. 3. Fixed the bug that Controller will print all Voucher codes even only some of the codes are selected.
Notes: 1. To use Omada Controller 3.2.x new features, you need to upgrade your EAP's firmware to the corresponding version. 2. Once upgraded to this version of Omada Controller, you will NOT be able to downgrade to an earlier version. 3. Portal configuration will be lost after upgrading to Omada Controller 3.2.X from 2.4.X or earlier version. |
Kiadás dátuma: 2019-07-04 | Nyelv: Angol | Fájlméret: 124.2MB |
Operációs rendszer: Windows 7/8/10/Server |
||
New Feature/Enhancement: 1. Optimize the performance of Controller to manage up to 1500 EAPs. 2. Optimize the interactive process between EAP and Controller to decrease the process time. 3. Limit the entry number of client/client history/guest to 1.2 million/1.2 million /6 million. 4. Optimize display page of map and log when there are a lot of entries.
Bug Fixed: 1. Fixed the bug that CPU and memory may be highly used when Fast Roaming is enabled. 2. Fixed the bug that Omada Controller reports timeout error when adopting multiple EAPs simultaneously. 3. Fixed the bug that Controller will print all Voucher codes even only some of the codes are selected.
Notes: 1. To use Omada Controller 3.2.x new features, you need to upgrade your EAP's firmware to the corresponding version. 2. Once upgraded to this version of Omada Controller, you will NOT be able to downgrade to an earlier version. 3. Portal configuration will be lost after upgrading to Omada Controller 3.2.X from 2.4.X or earlier version. |
Kiadás dátuma: 2019-03-08 | Nyelv: Angol | Fájlméret: 123.6MB |
Operációs rendszer: Windows 7/8/10/Server |
||
New Feature/Enhancement: 1. Merge 2.4GHz and 5GHz SSID. 2. Add Guest Network function. 3. Optimize log field and content. 4. Add SSID Radius accounting to WPA-Enterprise security mode. 5. Optimize the site list which allows us to inquire the specific site based on the site name and add new entrance for the hotspot. 6. Add SSL encryption in Log Server, and Log setting/Mail Server can be only accessed by administrator account. 7. Add Layer-3 Accessibility in SSH. 8. Add Mesh settings to Backup and Restore file. 9. Add CHAP encryption and NAS ID in Radius portal authentication and the Radius Client role is transferred from EAP to Omada Controller. 10. Add SSID MAC Authentication to none security mode. 11. Add channel utilization function. 12. Add Full-Sector DFS function in Mesh network. 13. Channel limit is revised from private configuration to site settings. 14. Support inputting domain name in SMTP server.
Notes: 1. The log will be cleared when you upgrade the software from version 3.0.x to version 3.1.4. 2. Add push notification to Omada APP of version 2.1.4 or above when EAP is connected/disconnected from Omada Controller. 3. This version of Omada Controller is applied to Omada APP of version 2.1.4 or above. 4. When you upgrade your controller or backup files from lower version, the 2.4GHz and 5GHz SSID entries with the same name will be merged and it will inherit the parameters of the original 2.4GHz SSID. 5. If you use External Radius Server with External Web Portal in old version controller, pay attention that the API has been changed in this version, thus you have to modify your External Web Portal, refer to FAQ-2390 for more details. 6. The log generated by EAP will be managed and storaged by Controller if you manage EAPs by Omada Controller. 7. Channel utilization will take effect only with new firmware. |
Kiadás dátuma: 2019-03-08 | Nyelv: Angol | Fájlméret: 127.5MB |
Operációs rendszer: Windows 7/8/10/Server |
||
New Feature/Enhancement: 1. Merge 2.4GHz and 5GHz SSID. 2. Add Guest Network function. 3. Optimize log field and content. 4. Add SSID Radius accounting to WPA-Enterprise security mode. 5. Optimize the site list which allows us to inquire the specific site based on the site name and add new entrance for the hotspot. 6. Add SSL encryption in Log Server, and Log setting/Mail Server can be only accessed by administrator account. 7. Add Layer-3 Accessibility in SSH. 8. Add Mesh settings to Backup and Restore file. 9. Add CHAP encryption and NAS ID in Radius portal authentication and the Radius Client role is transferred from EAP to Omada Controller. 10. Add SSID MAC Authentication to none security mode. 11. Add channel utilization function. 12. Add Full-Sector DFS function in Mesh network. 13. Channel limit is revised from private configuration to site settings. 14. Support inputting domain name in SMTP server.
Notes: 1. The log will be cleared when you upgrade the software from version 3.0.x to version 3.1.4. 2. Add push notification to Omada APP of version 2.1.4 or above when EAP is connected/disconnected from Omada Controller. 3. This version of Omada Controller is applied to Omada APP of version 2.1.4 or above. 4. When you upgrade your controller or backup files from lower version, the 2.4GHz and 5GHz SSID entries with the same name will be merged and it will inherit the parameters of the original 2.4GHz SSID. 5. If you use External Radius Server with External Web Portal in old version controller, pay attention that the API has been changed in this version, thus you have to modify your External Web Portal, refer to FAQ-2390 for more details. 6. The log generated by EAP will be managed and storaged by Controller if you manage EAPs by Omada Controller. 7. Channel utilization will take effect only with new firmware. |
EAP felderítő
The EAP Discovery Tool can help the EAP Controller to adopt the EAP in L3 Network, and you can also use the EAP Discovery Tool to find the EAP’s IP address.
Kiadás dátuma: 2019-06-14 | Nyelv: Angol | Fájlméret: 23.54 MB |
Operációs rendszer: WinXP/Vista/7/8/8.1/10/Server2008/Server2012/Mac OS X 10.7/10.8/10.9/10.10/10.11 |
||
Bug fixed: 1. Fixed the bug that when the Discovery Utility issues Controller_IP to EAPs which are in factory status, Controller cannot batch manage the EAPs. 2. Fixed the bug that sometimes the Discovery Utility cannot find all EAPs when running in MacOS. Note: 1. This version of software can be used in both Windows and Mac operation system. 2. Double click the software or run the command “java –jar **.jar” to run the software on MacOS(**.jar is the name of this software). 3. To run this software, you need to install JRE 8.0 on your PC. |
Kiadás dátuma: 2018-07-24 | Nyelv: Angol | Fájlméret: 84.16 MB |
Operációs rendszer: Mac OS X 10.7/10.8/10.9/10.10/10.11 |
||
New Feature/Enhancement: |
MIB fájlok
Kiadás dátuma: 2017-04-15 | Nyelv: Angol | Fájlméret: 2.81 KB |
Notes: EAP225_V2_170303 frissítéshez/készülékhez.
|